Librarian View

LEADER 05826cam a2200697Ii 4500
001 16009810
005 20210929230152.0
006 m o d
007 cr |n|||||||||
008 200828s2020 enk ob 101 0 eng d
015
  
  
|a GBC094108 |2 bnb
016
7
  
|a 019859272 |2 Uk
019
  
  
|a 1195467919 |a 1197752523
020
  
  
|a 9780128233368 |q electronic book
020
  
  
|a 0128233362 |q electronic book
020
  
  
|z 9780128233320
020
  
  
|z 012823332X
035
  
  
|a (OCoLC)on1190855079
035
  
  
|a 16009810
037
  
  
|a 9780128233368 |b Ingram Content Group
040
  
  
|a YDX |b eng |e rda |c YDX |d OPELS |d YDXIT |d UKAHL |d UKMGB |d OCLCF |d EBLCP
050
  
4
|a TJ930 |b .C67 2020
245
0
0
|a Corrosion under insultation (CUI) guidelines : |b technical guide for managing CUI / |c edited by Gino De Landtsheer.
250
  
  
|a Third edition.
264
  
1
|a Duxford ; |a Cambridge, MA : |b Woodhead Publishing, |c [2020]
300
  
  
|a 1 online resource.
336
  
  
|a text |b txt |2 rdacontent
337
  
  
|a computer |b c |2 rdamedia
338
  
  
|a online resource |b cr |2 rdacarrier
490
1
  
|a European Federation of Corrosion Publications ; |v number 55
500
  
  
|a Includes index.
504
  
  
|a Includes bibliographical references and index.
506
  
  
|a Access restricted by licensing agreement.
588
  
  
|a Description based on online resource; title from digital title page (viewed on September 10, 2020).
505
0
  
|a Intro -- Corrosion Under Insulation (CUI) Guidelines: Technical Guide for Managing CUI -- Copyright -- Dedication -- Contents -- European Federation of Corrosion (EFC) publications: Series introduction -- Volumes in the EFC series list -- 1 Introduction -- 1.1 Purpose of the document -- References -- 2 Economic consideration -- 2.1 Statistical analysis -- 2.2 Size of the issue -- 2.2.1 Safety and integrity -- 2.2.2 Environment -- 2.2.3 Revenue or production loss -- 2.2.4 Reputation -- 2.2.5 Collateral damage cost -- 2.2.6 Online leak sealing cost
505
8
  
|a 2.2.7 Repair and/or replacement, fabrication and installation costs -- 2.2.8 Fitness for continued service -- 2.2.9 On-stream inspection and non-destructive examination and testing -- 2.3 Key performance indicators -- 3 Ownership and responsibility -- 3.1 Senior management -- 3.2 Engineering manager -- 3.3 Maintenance -- 3.4 Operations -- 3.5 Inspection -- 3.6 Members of a project team -- Corrosion-under-insulation program -- 3.7 Engineering and EPC(m) -- 4 The risk-based inspection methodology for CUI -- 4.1 Introduction -- 4.2 High-level prioritization
505
8
  
|a 4.2.1 Health & safety consequences (A) -- 4.2.2 Environmental consequences (B) -- 4.2.3 Economic consequences (C) -- 4.2.4 Impact on reputation (D) -- 4.3 Data validation -- 4.3.1 The need for data validation -- 4.3.2 Different aspects of a data validation -- 4.3.3 Implementation of data validation -- 4.3.4 CUI and mothballing of equipment -- 4.4 Challenging the need for insulation -- 4.5 Using RBI to design CUI inspection plans -- 4.5.1 Preparation of an RBI analysis -- 4.5.2 Susceptibility factors -- 4.5.2.1 Operating temperature -- 4.5.2.2 Coating status
505
8
  
|a 4.5.2.3 Cladding/insulation condition -- 4.5.2.4 Available corrosion allowance -- 4.5.2.5 External coil/steam tracing -- 4.5.2.6 External environment -- 4.5.3 Qualitative RBI analysis -- 4.5.4 Semiquantitative RBI analysis -- 4.5.4.1 Consequence of CUI failure -- 4.5.4.2 Probability of CUI failure -- 4.5.4.3 Risk of CUI failure -- 5 Inspection activities and strategy -- 5.1 General considerations -- 5.2 Typical locations on piping circuits susceptible to corrosion-under-insulation -- 5.3 Typical locations on equipment susceptible to corrosion-under-insulation
505
8
  
|a 5.3.1 Vessels, columns and tanks -- 5.3.2 Heat exchangers -- 5.4 Examples of a risk-based inspection plan -- 5.4.1 Evaluated risk level: High-extreme -- 5.4.2 Evaluated risk level: Medium-high -- 5.4.3 Evaluated risk level: Medium -- 5.4.4 Evaluated risk level: Low -- 5.4.5 Evaluated risk level: Negligible -- 6 Non-destructive examination and testing screening techniques for corrosion-under-insulation -- 6.1 Non-destructive examination and testing techniques -- Reference -- 7 Recommended best practice to mitigate CUI -- 7.1 Background -- 7.1.1 Key parameters -- 7.1.2 Assumptions
590
  
  
|a Access is available to the Yale community.
650
  
0
|a Piping |x Corrosion.
650
  
0
|a Pipelines |x Protection. |0 http://id.loc.gov/authorities/subjects/sh85102382
650
  
0
|a Pipelines |x Cathodic protection. |0 http://id.loc.gov/authorities/subjects/sh85102374
650
  
0
|a Corrosion and anti-corrosives. |0 http://id.loc.gov/authorities/subjects/sh85033050
650
  
7
|a Corrosion and anti-corrosives. |2 fast |0 (OCoLC)fst00880341
650
  
7
|a Insulation (Heat) |2 fast |0 (OCoLC)fst00974462
655
  
0
|a Electronic books.
700
1
  
|a De Landtsheer, Gino, |e editor.
710
2
  
|a Materials Research Society. |b Fall Meeting |d (2013 : |c Boston, Mass.) |0 http://id.loc.gov/authorities/names/nb2014018431
730
0
  
|a Knovel. |g OCLC KB.
776
0
8
|c Original |z 012823332X |z 9780128233320 |w (OCoLC)1144105756
830
  
0
|a Publications (European Federation of Corrosion) ; |v no. 55. |0 http://id.loc.gov/authorities/names/n88523859
852
8
0
|b yulint |h None |z Online resource
852
8
0
|z Online resource
856
4
0
|y Online book |u https://yale.idm.oclc.org/login?URL=https://app.knovel.com/hotlink/toc/id:kpCICUIGT2/corrosion-under-insulation?kpromoter=marc
901
  
  
|a TJ930
902
  
  
|a Yale Internet Resource |b Yale Internet Resource >> None|DELIM|15953236
905
  
  
|a online resource
907
  
  
|a 2021-09-29T09:38:14.000Z
946
  
  
|a DO NOT EDIT. DO NOT EXPORT.
953
  
  
|a https://app.knovel.com/hotlink/toc/id:kpCICUIGT2/corrosion-under-insulation?kpromoter=marc
Timestamp: 2024-08-28T10:23:52.603Z

Subject Authorities

Variants from 943231 (matched with [Corrosion and anti-corrosives])

Anti-corrosive paint
Atmospheric corrosion
Metal corrosion
Rust
Rustless coatings
Timestamp: 2024-08-26T15:49:03.991Z

Variants from 980130 (matched with [Pipelines])

Pipe lines
Timestamp: 2024-08-26T15:49:14.728Z

Variants from 1323356 (matched with [Piping])

Pipe lines
Piping systems
Timestamp: 2024-08-26T15:51:18.816Z